Built-in Double Dimmer EDD-T42

The flush-mounted LED Double Dimmer EDD-T42 with central plate is a double dimmer for replacing series switches and for space-saving dimming of two light points. It is suitable for dimmable LED lamps, 230V incandescent lamps, halogen and low-voltage halogen lamps with magnetic transformer. For use in standard DIN 49073 flush-mount boxes with 60mm installation opening.

Quick Facts

  • replace series switch to double dimmer
  • dimming of 2 groups each 5-40W LED or 15-110VA (ohmic)

The dimmer is intended for installation in device sockets according to DIN 49073.

Power reduction of the maximum power indicated on the dimmer as a function of the ambient temperature:
The dimmer heats up during operation because a small part of the connected load is converted into heat. The specified nominal output is designed for installation of the dimmer in a solid stone wall. If the dimmer is installed in a wall made of gas concrete, wood, plasterboard or in a surface-mounted housing, the maximum connected load must be reduced by at least 20%. This reduction is also necessary if several dimmers are installed in a combination or if other heat sources lead to further heating.

Operating principle: leading edge
Control actuation: rotary dimmer with rotary-off-function
Shaft: 4 mm plastic
Connection: screw terminals up to 2 x 2.5 mm² (rigid)
Overtemperature protection: Thermal fuse
Short circuit/overload protection: Fine-wire fuse TlAH/25OV (incl. spare fuse)

Electrical Data

Mains supply 230 V ~ (+/-10%) / 50 Hz
Fuse protection Fine fuse T1AH / 250 V (incl. spare fuse)
Output 2x 5 - 40 W LED power or 2x 15 - 110 W/VA power (ohmic)
Short-circuit protection Electronic overload protection
Overtemperature protection Thermal fuse
Actuation Rotary dimmer with rotary-off-function
Connection screw terminals up to 2 x 2.5 mm² (rigid)
Operating temperature -10 °C to 30 °C
Storage temperature -10 °C to 40 °C
Humidity 0 % to 85 % non-condensing
Protection class IP 10
Protection class 2

Design, Dimensions, Weight

Design Flush-mounted installation for a switch box
Dimensions LxWxH 71x71x33 mm
Weight 94 g

Ordering Data and Conformity

Type designation EDD-T42
Article no. EH4200X0700, EH4260X0700 (with central plate)
Make Ehmann
Conformity CE, REACH, RoHS

Connection

 


Mounting

  1. Switch off power.
  2. Turn off the rotary knobs (1) via the stop.
  3. Remove nuts (2).
  4. Remove cover (3).
  5. Connect the device according to the wiring diagram. 
  6. Fasten the unit in the flush-mounted box using fastening claws or screws.
  7. Mount covers.
  8. Switch on power.

Instruction Manual and LED Compatibility List

Additional Equipment

Switch range adapter