Switching mechanism
|
Heart curve control
|
Actuating force
|
Circa 2.5N (with one contact element)
|
Button mounting
|
Central, by means of union nut made of metal
|
Protection class
|
IP40
|
Front frame material
|
Thermoplastic or aluminium alloy made of metal
|
Operating temperature
|
-30°C to +55°C
|
Service life (mechanical)
|
1,000,000 switching cycles
|
Contact element 5A
|
Plug-on mounting provided by customer
|
Housing material
|
Duroplast, self-extinguishing (UL 94 V0)
|
Contact material
|
Silver contact: hard silver alloy 2µm silver plated / gold contact: hard silver alloy 2µm silver plated and 0.4µm gold plated
|
Contact resistance
|
Contact silver plated < 50 mOhm, Contact gold plated < 30 mOhm
|
Number of contacts
|
Either 1Ö or 1S or 1Ö + 1S, or 2Ö + 2S per contact element. Max. 2 double contact elements per button
|
Type of connection
|
Plug-in connection for flat receptacles 2.8x0.5mm
|
Contact mechanics
|
Self-cleaning snap-action contacts with low bounce
|
Direct current load (ohmic)
|
5A/12V, 4A/24V, 3A/36V, 2A/48V, 1.5A/60V, 0.5A/125V, 0.3A/250V
|
Direct current load (inductive L/R = 15ms)
|
3A/12V, 2A/24V, 1.7A/36V, 1.5A/48V, 1.2A/60V, 0.3A/125V, 0.2A/250V
|
Switching capacity
|
5A 250V AC (cos 0.7), recommended fuse element: LS switch type C 6 A
|
Service life (electronic)
|
70,000 switching cycles 5A 250V (cos 0.7)
|
Vibration resistance
|
up to 55Hz at 1.5mm stroke.
|